MRJ-Laser's fiber laser cleaners of 200w and above are equipped with chillers. During the use of laser chillers, high temperature alarms of chillers are often encountered, especially in high temperature summers, the frequency of high temperature alarms of such chillers will be higher. So how to solve this situation? Possible causes and solutions for the high temperature alarm of the laser chiller.
Generally speaking, there are several situations when the laser chiller has high temperature alarm:
1. The cooling capacity of the matching laser chiller is insufficient.
In winter, the ambient temperature is low and the cooling effect is good, but in summer, the ambient temperature rises, which affects the normal heat dissipation of the chiller, resulting in insufficient cooling capacity of the chiller, and the cooling equipment cannot be effectively controlled. At this time, Cooling Times, as a professional chiller manufacturer, we recommend that you replace a laser chiller with a larger cooling capacity;
2. The laser water chiller accumulates dust, which affects the heat dissipation effect.
As the chiller is in operation, the dust-proof net and condenser fins of the chiller are easy to absorb dust and debris. If they are not cleaned for a long time, it will affect the cooling performance of the chiller. In winter, the ambient temperature is low, which has no obvious effect on heat dissipation, but in summer, the increase in ambient temperature greatly reduces the cooling effect of the chiller, resulting in insufficient cooling capacity of the chiller. The user can use air guns to clean the dust of the condenser of the chiller and remove and wash the dust-proof net to solve the problem of high temperature alarm of the laser chiller.
3. The outlet and inlet are not smooth.
The air outlet and inlet are not smooth, which affects the heat dissipation of the chiller, resulting in insufficient cooling capacity of the chiller, which causes a high temperature alarm during the operation of the chiller. Therefore, when the chiller is working, it is necessary to ensure that the air outlet and air inlet are unobstructed.
The above are the problems and solutions that are prone to occur when the laser chiller has a high temperature alarm. If the chiller does not work during use, and it still cannot be solved, it is recommended to contact us for after-sales assistance in time.